The actual product may differ slightly from the image.

SF6 gasAlternative arc quenching and insulating gases

GasSafetyMonitor

3-026-R200

Gas type
SF6 
Gas type
C4-FN 
Gas type
O2 
Gas type
CO2 
Gas type
SO2 
Gas type
CO 

The central control unit of the DILO room air monitoring system displays the measured values and messages from the connected sensors. These sensors measure the concentrations of various gases in the room air.

The monitor is used to display and record measured values and to register messages. The potential-free relays can be used to control further warning devices. Up to 32 sensors can be controlled and monitored. The proven DILO operating concept allows warning and alarm limit values to be managed and important sensor information to be accessed.

The sensors are installed using the plug & play method, making them extremely easy to use. Measured values and messages are stored and can be accessed on the 7’ colour touchscreen as required.

Advantages & functions

  • Different acoustic signals for messages such as error, warning and alarm
  • Coloured optical messages on both the monitor and the sensor
  • Stores the last 100 messages
  • Individual naming of the monitor and the connected sensors possible
  • Permanent display of the measured values of all connected sensors
  • Sensors are connected via an RJ45 cable (Ethernet and Power over Ethernet (PoE))
  • Up to three sensors can be connected and supplied directly to the monitor
  • Can be expanded to up to 32 sensors by using PoE switches
  • Max. cable length of 100m, transmission distance can be extended by using an intermediate PoE switch

Technical data

Dimensions (W x H x D) 238 x 213 x 77 mm
Weight 0.7 kg
Indication Colour touch screen 17.8 cm (7")
Connection Max. 32 sensors; up to 3 sensors directly on the monitor (PoE), additional sensors can be installed via PoE switch
Connection Ethernet; 4 RJ45 socket
Operating voltage 80 - 264 V AC
Operating voltage 113 - 370 V DC
Frequency 47 - 63 Hz
Ambient moisture max. 95 % relative moisture, non condensing
Operating temperature -10 to +40 °C
Storage temperature -20 to +60 °C
Protection class IP 41 
Sound level 75 dB integrated alarm

Optional accessories

External visual and acoustic alarm signal 230 V/AC 05-1093-R001
Learn more Add to cart
External visual and acoustic alarm signal 115 V/AC 05-1093-R003
Learn more Add to cart
1 m long RJ45 Ethernet cable 05-1587-R013
Learn more Add to cart
2 m long RJ45 Ethernet cable 05-1587-R010
Learn more Add to cart
5 m long RJ45 Ethernet cable 05-1587-R015
Learn more Add to cart
10 m long RJ45 Ethernet cable 05-1587-R019
Learn more Add to cart
20 m long RJ45 Ethernet cable 05-1587-R020
Learn more Add to cart
30 m long RJ45 Ethernet cable 05-1587-R021
Learn more Add to cart
60 m long RJ45 Ethernet cable 05-1587-R022
Learn more Add to cart
100 m long RJ45 Ethernet cable 05-1587-R024
Learn more Add to cart
5 Port PoE switch with power supply and housing 3-026-R201
Learn more Add to cart
8 Port PoE switch with power supply and housing 3-026-R202
Learn more Add to cart
Note

Note:

The Monitor can directly supply up to three Sensors without their own power supply. If more than three sensors are required, a maximum of two sensors can be connected to the monitor. The third connection is required for a PoE switch (with own power supply) connected downstream that integrates additional sensors.
An RJ45 Ethernet cable is necessary per connected Sensor (3-026-R205 - 235) and PoE Switch.
It is also possible to combine different Sensor types with each other, if desired.